Serial to Ethernet Converter
Modbus TCP/IP to Serial Modbus gateway — connect serial Modbus devices to an Ethernet-based SCADA system.
View detailsWe are an embedded products manufacturing company. Our major strength is engineering, design, development & customized solutions — built to your specification.
Trusted by leading organisations
We are an Embedded Products Manufacturing Company in the field of Data Acquisition, Monitoring, and Control systems. Our major strength is Engineering, Design, and Development & customized Solutions.
We have successfully designed & developed different products for business associates such as Indian Railway, GAIL, MSRTC, Prudent Control & many others — each designed according to the customer's specification with a satisfactory result.
We are a customer-focused organization with a very strong commitment to quality and service, and have built up an excellent reputation within the industry. You will find us competitive, responsive, and very easy to do business with. Many of our customers are longstanding and will testify to our commitment, flexibility, and ongoing support.
We offer the best quality products.
Fast track prototype to high volume in any mix.
Responsive and easy to do business with.
Tailored service to suit your needs.
Low cost business model enabling highly competitive pricing.
Industrial-grade hardware for communication, acquisition and control — designed, built and supported in-house.

Modbus TCP/IP to Serial Modbus gateway — connect serial Modbus devices to an Ethernet-based SCADA system.
View details
Serial (TTL) to Ethernet module with virtual COM port mode — bring legacy serial devices onto the network.
View details
8-channel 16-bit analog input with 4 digital inputs and 8 open-collector outputs over MODBUS RTU.
View detailsOptically-isolated digital I/O interface for switching, status monitoring and alarm handling over RS-485.
View detailsRemote telemetry over GPRS/GSM — real-time monitoring of assets across distributed sites, no wiring needed.
View detailsBespoke hardware and firmware engineered to your exact application — concept and design through to production.
View detailsWe have designed and developed products for these organisations, each built to their specification.
Tell us your requirement and our team will design it for you.
#104 Bldg No. 13, Unnati UL-2, Sector-19, Ulwe, Navi Mumbai, Maharashtra — 410206, India
Need assistance? Our customer service assists you. Call us for your inquiry.
+91 73040 89969
Just send an email to us and ignite the conversation. Our team will reply in a few hours.
[email protected]
Fill in the form and we'll get back to you shortly.

This board is a Modbus TCP/IP to Serial Modbus converter board. It is very useful for connecting a serial device, with Modbus protocol, to an Ethernet-based SCADA system. There are three types of isolated serial outputs available (i.e. RS-485). It converts received TCP/IP Modbus commands to serial Modbus format and sends them to the serial slave device(s) connected to it, and also converts the response from a slave, in serial Modbus format, to Modbus TCP/IP format and sends it to the master over Ethernet.
| Baud Rate Supported | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
|---|---|
| Core Module Memory | 64KB Flash, 4KB RAM |
| Ethernet | 10/100Mbps |
| Dimension | 130 x 75 x 35 mm |
| Power Consumption | 50mA @ 24V, 2 Watt max |
Interested in this product?
Contact Us
This module is a Serial (TTL)-to-Ethernet converter module. It is very useful for connecting a legacy serial device to an Ethernet network. It supports a virtual mode of operation, in which the board can be configured as a PC COM port — enabling legacy application software based on a standard PC COM port to run seamlessly.
| Baud Rate Supported | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
|---|---|
| Core Module Memory | 64KB Flash, 4KB RAM |
| Ethernet | 10/100Mbps |
| Dimension | 60 x 30 x 25 mm |
| Power Consumption | 300mA @ 5V, 2 Watt max |
Interested in this product?
Contact Us
This is an 8-channel 16-bit analogue input board with an additional 4 channels of digital input and 8 channels of digital open-collector output. The ADC used is of sigma-delta type with high accuracy, and the sampling rate is programmable through MODBUS registers. The 4 digital inputs are multipurpose — usable as a simple digital input, a resettable counter, or an RPM counter. The card has an RS-232/422/485 interface supporting the MODBUS RTU protocol.
| Communication | RS-485 serial port, 1200 to 230400 bps (Default 9600 bps) |
|---|---|
| Protocol | MODBUS Protocol (RTU Mode) |
| Supply | 24V input power supply |
| Miscellaneous | Built-in temperature sensor |
Interested in this product?
Contact UsA versatile digital I/O interface card built for industrial automation and control. It provides multiple optically-isolated digital input channels and open-collector / relay-driver output channels, communicating over RS-485 using the MODBUS RTU protocol. Ideal for switching, status monitoring, alarm handling and control of field devices in SCADA and PLC environments.
Need this for your project?
Contact UsA remote data-acquisition and telemetry solution that collects field data from sensors and transmits it to a central server over the GPRS / GSM cellular network. It enables real-time remote monitoring of assets spread across geographically distributed sites without any wired infrastructure — well suited to utilities, water management, energy metering and environmental monitoring.
Need this for your project?
Contact UsBespoke hardware and firmware engineering tailored to your exact application. From concept and schematic design through firmware development, prototyping and production, our team builds embedded solutions around your specifications — protocol converters, data loggers, control boards and IoT gateways. Tell us your requirement and we will design it for you.
Tell us your requirement.
Contact Us